Power to People
Public launch Q2 2027
For New Zealand hotels

Take control of your energy.

See how your hotel's energy use compares with hotels like it, then work through a guided energy audit. Your team does it themselves, at their own pace.

We'll only use your email to tell you when Power to People opens, and never share it. You can ask us to see or delete it at any time. Privacy statement

A Remarkable Hotel, Queenstown
From bills to a plan
Steps
Good practiceTypicalHigh
Above typical for a hotel like yours

DIY energy audit tool, built for the people who run the building

01

Benchmark

Upload your billing data and see how you compare to other hotels in your category and region.

Your headline
11,800
kWh per room a year
YouGood practiceTypical
Monthly energy
Where the energy goes
  • Heating 43%
  • Catering 20%
  • Hot water 17%
  • Lighting 12%
  • Other 7%
  • Cooling 1%
Energy, carbon and cost by fuel
Energy
  • Electricity 25%
  • Gas / oil 75%
Carbon
  • Electricity 12%
  • Gas / oil 88%
Cost
  • Electricity 43%
  • Gas / oil 57%
02

Guided energy audit

A walkthrough energy audit your team can work through at their own pace. Find the saving opportunities yourself.

O&M manual upload
PDF
Boiler 1 – O&M manual.pdf
Output250 kW
FuelNatural gas, condensing
Service intervalEvery 12 months
3 details found · check and confirm
Site Mode
Automatically upload data from photos on site.
MODEL CB-250
OUTPUT 250 kW
FUEL NAT GAS
YEAR 2014
Boiler 1 · 250 kW · 2014
Confirm
Asset management
Audit checklist
Heating
Does the boiler incorporate weather compensation appropriately?
YesNoNot sure
Do circulation pumps/fans have variable speed drives (VSD)?
YesNoNot sure
Leaks, unusual noise, or vibration?
YesNoNot sure
Your hotel's assistant
Why is our gas use still high in summer?
Boiler 1 heats your hot water as well as the radiators, so it runs all year. Start with the heating time schedule in your audit, then check the boiler's summer controls.
From your asset scheduleOpen the audit question →
Ask about your hotel…
03

Tailored actions

Actions ranked by payback and by carbon, kept separate, with a clear flag and a bespoke follow-on scope list when an engineer is needed on site.

Recommendations
Very high payback potential · typically under 1 year
Match heating times to occupancy
High payback potential · typically 1–2 years
Fit weather compensation to the heating circuit
Medium payback potential · typically 2–5 years
Add variable speed drives to the heating pumps
Low payback potential · typically over 5 years
Plan the boiler replacement
Follow-on survey scope
Follow-on survey scope
For an engineer to price and visit
  1. 1Boiler 1: condition and combustion check
  2. 2Heating pumps: confirm speed control
  3. 3Switchboard: capacity for a heat pump
The items that need an engineer on site, highest impact first.
Energy Audit Summary Report
Energy Audit Summary Report
A Remarkable Hotel, Queenstown
A report for your general manager, ready to print or share.
Asset replacement
Boiler 2
Gas · non-condensing · 1998
Past its expected life
Replace withan air-to-water heat pump
Carbon90–105 t CO₂e lessa year
Running cost$8k–16k lessa year, at your confirmed rates
!Professional follow-on survey required to verify feasibility.

Designed in Queenstown, New Zealand, by a chartered building services engineer, grounded in recognised engineering guidance.